R407C Refrigerant – Proven R22 Replacement for Air Conditioning and Heat Pump Systems

R407C Refrigerant – Proven R22 Replacement for Air Conditioning and Heat Pump Systems

  • High-quality refrigerants
  • Tested quality & safety
  • Free Shipping
Regular price 399,00 €
Regular price 0,00 € Sale price 399,00 €
Unit price 39,90 €  per  kg
Save 0% Sold out

Order now and receive on

  • Top quality & lightning-fast shipping!

    I've ordered from here several times and I'm always impressed. The refrigerants are high-quality, exactly as described, and delivery is always super fast. I especially like that the shop only offers tested quality – you can buy with a clear conscience! ★★★★★

  • Reliable and fair!

    I ordered R134a for my air conditioning service equipment and am more than satisfied. The prices are fair, shipping was faster than expected, and the product arrived perfectly packaged. The customer service is also top-notch—friendly and competent. ★★★★★

  • My new favorite shop for refrigerants!

    Great selection, fair prices, and top-notch service! I've been searching for a reliable source of refrigerant for a long time and finally found a trustworthy supplier here. The order process went smoothly, and shipping was extremely fast. ★★★★★

  • Free Shipping
  • Top quality
  • Secure payment

Description

Produktinformationen

R407C Kältemittel ist ein HFC-Gemisch aus R32, R125 und R134a. Es wird in Klimaanlagen, Wärmepumpen und gewerblichen Kühlanwendungen eingesetzt und gilt als bewährte Retrofit-Lösung für geeignete R22-Bestandsanlagen.

Geliefert wird eine original versiegelte 10-kg-Flasche im aufladbaren Zylinder mit 1/4 Anschluss. Der Zylinder ist im Preis enthalten. Flaschendesign und Farbe können aufgrund des Mehrweg-/Tauschsystems abweichen.

Vorteile dieses Produkts

  • R407C Klimagas / Kältemittel
  • 10 kg Füllgewicht
  • Aufladbarer Zylinder mit 1/4 Anschluss
  • Bewährte Alternative für geeignete R22-Bestandsanlagen
  • Geeignet für Klimaanlagen, Wärmepumpen und gewerbliche Kühlung

Anwendungsbereiche

Klimaanlagen, Split-, Kompakt- und VRF-Systeme, Wärmepumpen, gewerbliche Kühlung, Kühlräume, Supermarkt-Kühlmöbel und Retrofit-Projekte für geeignete R22-Anlagen.

Shipping information

Shipping costs
We ship within Germany. Shipping is completely free!

Shipping time
We know how important fast and secure deliveries are. Therefore, your order will be carefully packaged and insured within Germany to ensure it arrives safely. Delivery time is typically 1-3 business days , so you can have your desired products in your hands soon.

View full details
Selected Variant Image
R407C Refrigerant – Proven...
Regular price 399,00 €
Regular price 0,00 € Sale price 399,00 €
Unit price 39,90 €  per  kg
Selected Variant Image
R407C Refrigerant – Proven...
Regular price 399,00 €
Regular price 0,00 € Sale price 399,00 €
Unit price 39,90 €  per  kg

R407C is an established HFC refrigerant for air conditioning, heat pump, and commercial refrigeration applications, characterized by its R22-like performance and broad system compatibility. It is used in split systems, VRF units, and heat pumps and has been considered a standard retrofit solution for existing R22 systems for years. At Voll Gas, you can get R407C refrigerant with a 10 kg filling weight in a refillable cylinder with a 1/4-inch connection for safe filling and maintenance of your systems. 

The correct filling quantity and a tested product are crucial for reliable operation. Our products are tested, quickly available, and comply with applicable safety standards. 

Products and Filling Quantities 

R407C refrigerant is designed for air conditioning systems and heat pumps that previously operated with R22 or are designed for R407C from the outset. The 10 kg cylinder with a refillable cylinder and 1/4-inch connection is suitable for maintenance work on existing systems as well as for new installations in the commercial sector. The cylinder is included in the price. 

An overview of common application areas: 

Application 

Typical system 

Temperature range 

Air conditioning 

Split, compact, and VRF systems 

MT 

Heat pumps 

Residential and commercial heat pumps 

MT 

Commercial refrigeration 

Cold rooms, supermarket refrigerators 

MT 

Retrofit 

Existing R22 systems 

MT 

For specialist companies that manage multiple systems, the 10 kg cylinder is an economical choice. Make sure to only stock the amount you need in the short term, and observe legal storage requirements for fluorinated greenhouse gases. 

What is R407C? Properties and Use 

R407C is a ternary HFC refrigerant mixture of R32, R125, and R134a. It was developed to replace R22 in existing and new systems without the ozone-depleting potential of its predecessor. The GWP value is ~1774 – significantly lower than older HCFC refrigerants, but higher than newer alternatives such as R32 or R449A. Safety class A1 designates it as non-flammable and non-toxic. 

The refrigerant is mainly used in air conditioning systems and heat pumps that previously operated with R22. Due to its temperature glide (~7 K), particular care is required in system design. The most important technical properties of R407C: 

  • No ozone depletion potential: ODP = 0, completely ozone-friendly 

  • Safety class A1: Non-flammable, low toxicity 

  • R22-like performance: Allows for retrofit without complete system replacement 

  • Temperature glide ~7 K: Requires careful system adjustment when converting 

  • Broad applicability: Suitable for split, VRF, and heat pump systems 

Handling requires care and valid certification according to Art. 10 (1) of Regulation (EU) 573/2024. Installation and filling may only be carried out by trained specialists. 

R407C as a retrofit solution for R22 systems 

R407C was specifically developed for retrofitting existing R22 systems. Its performance data is similar to R22, allowing for a direct replacement in many systems. However, an oil change to POE oil is required for retrofitting, as R407C is not compatible with the mineral oil commonly used in R22 systems. The system must be professionally inspected before any retrofit. 

The temperature glide of ~7 K is a significant difference compared to pure refrigerants like R32. It occurs because the components of the mixture evaporate and condense at different temperatures. This affects the design of heat exchangers and expansion valves. Older systems designed for R22 can usually be converted to R407C – however, a professional inspection and, if necessary, replacement of components are essential. Use only refrigerants that comply with EN 378 and ISO 817 standards. 

Safety, Storage, and Disposal 

R407C belongs to safety class A1 and is considered non-flammable. Nevertheless, basic safety measures must be observed during handling. Avoid direct skin contact with liquid refrigerant and work in well-ventilated areas, as released gas can displace oxygen. The safety data sheet contains all relevant information on hazards, protective measures, and first aid – read it carefully before use. 

The most important safety instructions for working with R407C refrigerant: 

  • Ensure ventilation: Work in well-ventilated areas or outdoors 

  • Wear protective equipment: Use safety glasses and gloves when handling 

  • Perform leak check: Check connections before and after filling 

  • Observe pressure limits: Never exceed permissible operating pressures 

  • Have an emergency plan ready: Know first aid measures in case of skin contact or inhalation 

Store containers upright in cool, dry rooms, protected from direct sunlight and heat sources above 50 °C. Keep refrigerant cylinders away from flammable materials and secure them against tipping. Disposal is subject to legal regulations for fluorinated greenhouse gases – refrigerant must not be released into the atmosphere. Empty or partially empty containers must be disposed of via certified disposal companies or return systems. 

Voll Gas – your partner for all types of refrigerants 

At Voll Gas, you receive R407C refrigerant of tested quality, delivered quickly and reliably. Our product range covers the most common refrigerants for air conditioning systems, heat pumps, commercial refrigeration, and vehicle air conditioning. We value transparency, safety, and expert advice to help you make the right choice for your application. 

In addition to R407C, we offer other refrigerants for various systems – from R410A and R32 for modern air conditioning systems, to R449A for commercial refrigeration systems, and R134A for vehicle air conditioning systems. Our team is available to answer your questions regarding compatibility, fill quantities, and safety instructions. Order R407C refrigerant conveniently online now and benefit from free shipping within Germany. 

R407C Refrigerant FAQ 

In practice, R407C often raises questions about compatibility, retrofitting, and correct handling. Here are the answers to the most important ones. 

What is R407C and what is it used for? 

R407C is a ternary HFC mixture of R32, R125, and R134a, developed as a replacement for R22. It is mainly used in air conditioning systems, heat pumps, and commercial refrigeration applications in the medium temperature range. 

Can I use R407C directly as a replacement for R22? 

A retrofit is possible in many cases but requires an oil change to POE oil, as R407C is not compatible with mineral oil. Additionally, the system must be professionally checked to ensure that compressors, expansion valves, and seals are suitable for operation with R407C. 

What does temperature glide mean for R407C? 

R407C is a refrigerant blend whose components evaporate and condense at different temperatures. This so-called temperature glide of ~7 K affects system design and must be considered for heat exchangers and expansion valves. 

What certification do I need to purchase R407C? 

The purchase is exclusively reserved for holders of a valid certificate in accordance with Art. 10 Para. 1 of Regulation (EU) 573/2024 or representatives of certified companies. The refrigerant may only be acquired for the installation, maintenance, or servicing of corresponding facilities. 

How do I store R407C refrigerant correctly? 

Store the cylinder upright in a cool, dry room, protected from sunlight and temperatures above 50 °C. Keep the refrigerant away from flammable materials and secure the cylinder against tipping over. 

Can I return the deposit cylinder? 

Yes. Cylinders purchased from Voll Gas after February 28, 2024, can be returned in accordance with Art. 11 Para. 4 of Regulation (EU) 2024/573 with the provided return slip. A new return slip can be obtained via the contact form. 

How long does delivery take? 

Orders are shipped insured within Germany. Delivery time is usually 1-3 business days. Shipping is free for orders over €100.